Description
OCT made simple.
Our supreme experience in Spectral Domain OCT allows us to provide the market REVO 60 with redesign optics. The updated REVO 60 meets all demands in daily routine practice.
Technical Specifications
Technology | Spectral Domain OCT |
Scanning speed | 60 000 measurements per second |
Light Source | SLED Wavelength 850 nm |
Bandwidth | 50 nm half bandwidth |
Axial resolution | 2.8 μm digital, 5 μm in tissue |
Transverse Resolution | 12 μm, typical 18 μm |
Overall scan depth | 2.8 mm / ~6 mm in Full Range mode |
Scan range | Posterior 5 mm to 15 mm, Angio 3 mm to 6 mm, Anterior 3 mm to 18 mm |
Scan program | 3D, Angio¹, Full Range Radial, Full Range B-scan, Radial, B-scan, Raster, Cross, TOPO¹ , Biometry AL¹ |
Fundus image | Live Fundus Reconstruction |
Alignment method | Fully automatic, Automatic, Manual |
Retina analysis | Retina thickness, Inner Retinal thickness, Outer Retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, MZ/EZ-RPE thickness |
Angiography OCT¹ | Vitreous, Retina, Choroid, Superficial Plexus, RPCP, Deep Plexus, Outer Retina, Choriocapilaries, Depth Coded, SVC, DVC, ICP, DCP, Custom, Enface, FAZ, VFA, NFA, Quantification: Vessel Area Density, Skeleton Area Density, Thickness map |
Angiography mosaic | Acquistion method: Auto, Manual Mosaic modes: 10×6 mm, Manual up to 12 images |
Glaucoma analysis | RNFL, ONH morphology, DDLS, OU and Hemisphere asymmetry, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, Structure + Function² |
Anterior | Pachymetry, Epithelium map, Stroma map, AIOP, Angle Assessment, AOD 500/750, TISA 500/750 |
Anterior (no lens/adapter required) | Anterior Chamber Radial, Anterior Chamber B-scan, Angle to Angle view |
Biometry OCT | AL, CCT, ACD, LT, P, WTW |
IOL Calculator ³ | IOL Formulas: Hoffer Q, Holladay I, Haigis, Theoretical T, Regression II |
Corneal Topography Map¹ | Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height, KPI (Keratoconus Prediction Index) |
Connectivity | DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking |
Min. pupil size | 2.4 mm |
Focus adjustment range | -25D to +25D |
Dimensions (LxWxH) / Weight | 479 mm x 367 mm × 493 mm / 29 kg |
Fixation target | OLED display (The target shape and position can be changed), External fixation arm |
Power Supply / Consumption | 100 V to 240 V, 50/60 Hz / 90 VA to 110 VA |
¹ an optional software module
² via connection with PTS software version 3.4 or higher